To calculate gearbox output torque, divide the motor power delivered at the gearbox output by the output speed: Torque (N·m) = 9550 × Power (kW) ÷ Speed (rpm). If you know the motor’s input power and the gearbox ratio, first estimate output speed and account for gearbox efficiency: Output torque (N·m) ≈ 9550 × Motor power (kW) × Efficiency ÷ Output speed (rpm). For example, a 5.5 kW motor running at 1450 rpm through a 20:1 reducer with an assumed 90% efficiency produces an estimated output speed of 72.5 rpm and output torque of about 652 N·m.
These equations give a practical estimate for a steady operating condition, not a complete gearbox selection. Actual suitability also depends on the reducer’s rated torque, service factor, duty cycle, thermal capacity, and the load’s starting and shock requirements. I’ll show how to calculate the estimate, check the assumptions, and use the result when specifying an industrial gear reducer.
Rotational power is the product of torque and angular speed. In the units commonly used for industrial machinery, the conversion is: T (N·m) = 9550 × P (kW) ÷ n (rpm). Here, T is torque, P is power at the point being evaluated, and n is the rotational speed at that same point.
The speed and power values must refer to the same shaft. To calculate torque at a gearbox output shaft, use output power and output speed; do not combine motor input power with gearbox output speed without accounting for losses. If power is given in watts instead of kilowatts, convert it first by dividing by 1000.
For a reduction gearbox, the approximate output speed is the motor speed divided by the reduction ratio: nout ≈ nmotor ÷ i. In this expression, i is the reduction ratio, such as 20:1. This is a nominal relationship; the actual speed can vary with the motor’s operating speed and the equipment’s control method.
A gearbox does not transmit all input power because some power is lost, including through friction and other internal effects. Estimate output power as Pout = Pmotor × η, where η is the assumed efficiency expressed as a decimal. The resulting output torque estimate is Tout = 9550 × Pmotor × η ÷ nout.
Suppose an application uses a 5.5 kW motor at 1450 rpm, a 20:1 reduction gearbox, and a provisional gearbox efficiency assumption of 0.90. The estimated output speed is 1450 ÷ 20 = 72.5 rpm. Estimated output power is 5.5 × 0.90 = 4.95 kW.
Now apply the torque formula: 9550 × 4.95 ÷ 72.5 = approximately 652 N·m. This is a calculated estimate based on the stated inputs and assumed efficiency, not a verified rating for a particular reducer. Confirm the actual efficiency and permitted output torque with the gearbox supplier before finalizing the selection.
Goto WGT to know more.
A higher reduction ratio generally gives a lower output speed and a higher available output torque for a given input power, subject to gearbox losses and mechanical limits. The ratio does not create power: output power is lower than input power when losses are present. Therefore, a torque estimate should always be considered alongside the output speed and power needed by the machine.
For a quick cross-check, calculate motor shaft torque first with the motor’s power and speed, then multiply by the ratio and efficiency: Tout ≈ Tmotor × i × η. Using the example, motor torque is about 9550 × 5.5 ÷ 1450 = 36.2 N·m; 36.2 × 20 × 0.90 is approximately 652 N·m. Small differences between results can occur from rounding.
The formula estimates torque associated with power at a stated speed. It does not by itself establish whether a reducer can withstand startup loads, frequent starts and stops, impact loads, or short-duration peak torque. Conveyors, mixers, crushers, and other machinery can have different load patterns, so the operating profile matters as much as the steady-state calculation.
Check the manufacturer’s rated output torque and any stated service factor or load classification. Also verify that the output shaft, mounting arrangement, bearings, and thermal limits are suitable for the application. A calculated value below a catalog rating is a useful screening step, but it is not a substitute for checking all selection limits.
Before requesting a reducer quotation, assemble the motor power and operating speed, the required output speed or ratio, and the estimated output torque. Describe the driven machine and whether the load is steady, variable, or subject to frequent starts and impacts. Include the required duty pattern, mounting orientation, shaft arrangement, and any space or environmental constraints.
These details help a supplier assess more than the basic torque equation. At WGT, we can review the operating information you provide and discuss an industrial gear reducer configuration against the application requirements. Where a value is unknown, identify it as an estimate so that the selection can be checked rather than treated as a confirmed design condition.
To calculate gearbox output torque from motor power and rpm, use T (N·m) = 9550 × P (kW) ÷ n (rpm) with output power and output speed. When you begin with motor power, estimate output speed from the ratio and reduce input power by the gearbox efficiency before calculating torque. In the worked example, 5.5 kW at 1450 rpm with a 20:1 ratio and assumed 90% efficiency gives an estimated output torque of about 652 N·m at 72.5 rpm.
Next, confirm the actual operating conditions and compare the estimate with the gearbox’s rated torque, service requirements, and thermal limits. Share your motor data, output speed, load type, and duty cycle with WGT when you need support evaluating an industrial gear reducer for your machinery project.
Contact us to discuss your requirements of How to Calculate Gearbox Output Torque from Motor Power and RPM. Our experienced sales team can help you identify the options that best suit your needs.