A prestressed tendon anchorage system transfers force from a tensioned tendon into a concrete structure or other designed anchorage zone. Choosing a compatible system means matching the tendon, wedges or grips, anchorage hardware, duct and stressing equipment to the project design—not selecting an anchor head in isolation. I recommend confirming the complete assembly against the approved drawings and applicable project requirements before ordering. This guide explains the main components, key selection checks and information to prepare when requesting a quotation or technical review.
If you are looking for more details, kindly visit our website.
This guide is for contractors, engineers, distributors and procurement teams sourcing components for post-tensioned concrete or other prestressed applications. It is also useful when comparing suppliers or checking whether replacement parts will work with an existing installation. The correct configuration depends on the tendon type, design force, installation method and anchorage-zone details. Where design information is incomplete, involve the project engineer before making a substitution.
A tendon is tensioned to introduce a planned force into a structural member. At the stressing end, wedges or another specified gripping mechanism hold the tendon after the stressing equipment is released. The anchor head and bearing plate transfer that force into the concrete anchorage zone; the surrounding concrete and reinforcement must be designed to accommodate the resulting stresses.
Some systems also include a duct or sheathing, a trumpet or transition, a fixed-end anchorage, and protection materials such as grout or corrosion-inhibiting components. The exact arrangement varies between bonded and unbonded systems, internal and external tendons, and different project applications. These components work as a coordinated system, so a part that appears dimensionally similar may not be functionally interchangeable.
| Component | Role in the assembly | Compatibility check |
|---|---|---|
| Tendon or strand | Carries the prestressing force through the member. | Confirm tendon type, nominal size, strand count and project specification. |
| Wedges or grips | Grip the tendon at the anchorage as specified by the system. | Match the wedge profile and size to the tendon and anchor head. |
| Anchor head and bearing plate | Hold the tendon and distribute force into the anchorage zone. | Check the system designation, dimensions and design documentation. |
| Duct, sheathing and transition | Provide the specified tendon path and separation or protection. | Verify routing, connection details and the requirements for bonded or unbonded construction. |
| Stressing equipment | Applies the specified stressing operation. | Confirm the jack and accessories suit the tendon and anchorage configuration. |
Anchorage systems are designed around a particular tendon arrangement and application. A system for a multi-strand post-tensioned member is not automatically suitable for a bar tendon, an unbonded single-strand tendon or a ground anchor. Even within one application, the stressing-end and fixed-end details may differ. Use the project’s system designation and drawings as the primary reference.
As a practical reference, prestressing strand commonly has a seven-wire construction, and project documents may specify nominal strand sizes such as 12.7 mm or 15.2 mm. These are examples, not a complete specification or confirmation that a particular anchorage accepts either size. The strand grade, strength, tolerances and applicable standards must also match the design and supplier documentation.
Hardware material, surface treatment and corrosion protection should be selected according to the exposure conditions and project requirements. Do not assume that a coating, wedge or protection method used on one system is suitable for another. Ask the supplier to identify the materials and finishes offered for the specified configuration, and have any proposed alternative reviewed by the responsible engineer.
Start by identifying whether the tendon is internal or external, bonded or unbonded, and stressed from one end or both ends. Then confirm whether the package requires live-end and fixed-end components, ducts, couplers, grout-related accessories, protection materials or stressing equipment. Applications can include buildings, bridges and other concrete structures, but the design requirements and installation details vary by project.
Goto DALU to know more.
For ground or rock anchors, confirm that the proposed assembly is intended for that application and aligns with the specified tendon, corrosion-protection strategy, anchorage arrangement and installation method. A structural post-tensioning anchorage should not be treated as a ground-anchor solution unless the design and product documentation explicitly establish suitability. When the application is unclear, provide the supplier with the drawings and ask for a scope review rather than relying on product names alone.
Ask whether the wedges are specified for the exact tendon type and size, and whether the anchor head and bearing plate belong to the same documented system. Confirm the duct or sheathing interface, transition dimensions and end arrangement against the drawings. If a supplier proposes equivalent parts, request the technical basis and identify who must approve the substitution.
Compatibility is more than a dimensional fit. The assembly must perform within the project’s design assumptions and installation procedure, and the anchorage zone must be detailed for the forces involved. A component should not be accepted solely because it can be physically assembled with another part.
Price depends on the requested system configuration, quantities, materials, accessories, documentation and delivery destination. Minimum order quantities and lead times are supplier- and product-specific; I would not assume a standard MOQ or delivery period without a confirmed quotation. Custom details, special finishes or incomplete technical information may affect the quotation process and production planning.
For an accurate request, provide the required quantities by component, delivery location, target schedule and packaging requirements alongside the technical documents. Ask the supplier to state what is included, what is excluded, the applicable drawing revision and any assumptions behind the offer. This makes quotations easier to compare and helps reduce scope gaps between the design and procurement teams.
Evaluate suppliers on the clarity and completeness of their technical response as well as price. Ask them to distinguish confirmed information from assumptions, and to flag missing data rather than silently selecting a configuration. This approach supports a more traceable procurement decision without treating a quotation as a substitute for engineering approval.
To move forward, prepare the latest drawings, tendon schedule, project specification, quantities and delivery requirements. At DALU, we can use that information to understand the requested anchorage scope, review component interfaces and prepare a quotation or technical discussion based on the details provided. Contact our team with your project documents and questions, and obtain the responsible engineer’s approval for any proposed system change before procurement or installation.
Want more information on Prestressed Tendon Anchorage Systems? Feel free to contact us.