Post Tensioning Slab Strand: Types, Specifications, and Procurement Guide

24, Nov. 2026

 

Post Tensioning Slab Strand: Types, Specifications, and Procurement Guide

Post tensioning slab strand is high-strength steel strand used in tendons that are tensioned after concrete has been placed and gained the required strength. For many building projects, buyers compare seven-wire prestressing strand by diameter, tensile strength, relaxation class, applicable standard, and whether it will be used in a bonded or unbonded tendon system. Common nominal diameters include 12.7 mm and 15.2 mm, while 1860 MPa is a commonly specified tensile-strength grade; neither value should be treated as universal. The project drawings, governing standard, and engineer’s specification must determine the final selection.

Please visit our website for more information on this topic.

Who This Guide Is For

This guide is intended for contractors, structural engineers, post-tensioning system providers, distributors, and procurement teams sourcing strand for concrete slabs. It explains which product details to confirm before requesting a quotation and how to compare suppliers beyond the quoted price. It is not a substitute for structural design or the requirements of a proprietary tendon system.

What Post Tensioning Slab Strand Does

Prestressing strand is typically made from seven steel wires twisted into one strand. In a post-tensioned slab, the strand is installed within a tendon arrangement and tensioned using the specified procedure after the concrete reaches the required strength. The resulting prestressing force helps the engineered slab resist service loads and control behavior such as cracking and deflection.

Strand is only one component of the system. Depending on the design, the complete tendon may also involve ducts or sheathing, anchorages, wedges, and grout or corrosion-protection materials. Strand selection must therefore match the tendon design and installation method rather than being made as an isolated material choice.

Types, Materials, and Specification Options

Seven-Wire Strand and Relaxation Class

Seven-wire prestressing strand is a common product form for post-tensioning applications. Buyers may encounter low-relaxation and normal-relaxation classifications, depending on the applicable standard and project specification. Low-relaxation strand is widely specified in prestressing work, but the required class should be confirmed from the design documents rather than assumed.

Specifications may also identify the strand by nominal diameter, tensile strength, surface condition, and permitted dimensional or mechanical tolerances. Product terminology and test requirements can differ between standards and markets. Ask the supplier to state the exact standard and grade on its offer, and confirm that the corresponding documentation will be supplied with the shipment.

Bonded and Unbonded Tendons

“Bonded” and “unbonded” describe tendon systems, not simply two interchangeable strand materials. Bonded systems commonly use strand inside a duct that is grouted after stressing, while unbonded systems typically use individually protected strand within a sheath and lubricant. The strand specification, coating or protection requirements, anchorages, and installation details must be compatible with the system selected by the project team.

Common Reference Values

Specification item Common reference What buyers should verify
Nominal diameter 12.7 mm or 15.2 mm Confirm the drawing, standard, and required tolerance.
Tensile strength 1860 MPa is a common grade Check the specified grade and applicable test criteria.
Strand construction Seven-wire strand is common Confirm construction and product designation on the submittal.

These values are procurement references, not a design recommendation or a guarantee that a particular grade is available for every standard. Standards may define additional mechanical properties, sampling, testing, marking, and acceptance requirements. The project specification takes precedence where it is more restrictive.

Match Strand to the Project Application

Post-tensioned strand is used in building slabs and other concrete structures where the structural design calls for post-tensioning. The appropriate product depends on the structural calculations, tendon layout, stressing equipment, anchorage system, exposure conditions, and local code requirements. A strand that meets a general strength description may still be unsuitable if its dimensions, relaxation class, or documentation do not match the specified system.

Before sourcing, determine whether the project uses bonded or unbonded tendons and identify the system supplier or engineer responsible for compatibility. Confirm the strand diameter and grade directly against the approved drawings and material schedule. If drawings use a regional standard or a project-specific designation, provide the full reference to the supplier rather than relying on a short product name.

A Practical Strand Selection Framework

  1. Collect the governing documents.

    Gather the latest drawings, technical specification, material schedule, applicable standard, and any tendon-system requirements. Record revisions so quotations are based on the current scope. Resolve conflicts with the engineer or system provider before placing an order.

    Link to DALU

  2. Define the exact product.

    State the strand construction, nominal diameter, strength grade, relaxation class, and required standard. Include any requirements for surface condition, coil presentation, packaging, or marking. Do not substitute a “similar” grade without written approval from the responsible project party.

  3. Confirm system compatibility.

    Provide the tendon type and anchorage-system requirements to the supplier. Ask whether the offered strand designation is suitable for the specified system and request supporting product documentation. Final compatibility approval should remain with the engineer or authorized system provider.

  4. Plan quantity and delivery.

    Share the required net quantity, delivery location, requested shipment schedule, and packaging expectations. Ask how the supplier handles production planning, order changes, and partial shipments. Quantities and timing should be agreed in writing because availability depends on specification, order size, production schedule, and logistics.

  5. Review the submittal before release.

    Check the quotation and technical documents against the purchase order before authorizing production or shipment. Verify product descriptions, standards, quantities, packaging, inspection documents, and delivery terms. Keep the approved submittal available for receiving inspection and project records.

Pricing, Minimum Order, and Lead Time

Strand pricing can vary with steel-market conditions, grade, diameter, applicable standard, order quantity, packaging, and destination. Freight, export handling, inspection requirements, and delivery terms can also affect the total landed cost. For meaningful comparison, request quotations against the same technical specification and shipment basis.

Minimum order quantities and lead times are supplier- and order-specific, so buyers should request current written confirmation rather than rely on a generic estimate. Include the required delivery date and ask whether the quoted schedule covers production, inspection, documentation, and transport. If the project has staged pours or phased delivery, identify those dates early and confirm whether separate lots can be supplied and traced.

Supplier Evaluation Checklist

  • Does the quotation identify the strand construction, diameter, grade, relaxation class, and governing standard?
  • Can the supplier provide the requested technical and inspection documents for the offered product?
  • Are product markings, coil identification, and packaging suitable for receiving checks and site handling?
  • Has the supplier confirmed quantity, minimum order, delivery schedule, shipping terms, and any order assumptions in writing?
  • Is there a clear process for technical questions, document review, nonconforming material, and shipment updates?

Do not evaluate a supplier on unit price alone. A lower quotation may exclude required documents, packaging, inspection, or delivery services, making direct comparison difficult. Review the complete commercial and technical offer and document any approved deviations before issuing a purchase order.

How DALU Can Support Your Sourcing

At DALU, we work with B2B buyers sourcing post tensioning slab strand and can review the stated requirements before preparing a quotation. Send us the required diameter, strength grade, relaxation class, standard, quantity, destination, and target delivery window. Where a requirement is unclear or incomplete, we can identify the information needed to confirm the offer rather than assume a specification.

For an efficient inquiry, include the relevant specification pages or material schedule and indicate whether the tendon system is bonded or unbonded. We can then discuss product availability, applicable documentation, packaging, and shipping arrangements for the requested scope. Final product acceptance and structural suitability should be confirmed by the project engineer or authorized tendon-system provider.

Key Takeaways and Next Steps

  • Start with the approved project specification; common reference values such as 12.7 mm, 15.2 mm, and 1860 MPa do not replace design requirements.
  • Specify strand construction, diameter, strength grade, relaxation class, and governing standard together.
  • Confirm compatibility with the complete bonded or unbonded tendon system, including required protection and anchorage components.
  • Compare complete quotations covering documentation, packaging, quantity, delivery, and commercial terms.

To move from product research to procurement, prepare the project specification, confirm system compatibility, and request a quotation against the same defined scope from each supplier. Contact DALU with your technical requirements, order quantity, destination, and target schedule to discuss a suitable supply proposal. This process helps your team evaluate strand on verified project needs rather than on a product label or price alone.

Contact us to discuss your requirements of Post Tensioning Slab Strand. Our experienced sales team can help you identify the options that best suit your needs.